PRODUCTS AFFECTED
SOLUTION
IR remote interfaces in Rowe
jukeboxes.
PROBLEM
Add a .1 uf capacitor (p/n
70028511) from pin 1 (reset) of
US to ground on the IR remote
interface (see drawing)
The addition of the .01 uf cap
across R-91 on the CCC has
caused a reset problem with the
IR remote interface.
Use caution when changing the
CCC in a jukebox that has an IR
remote. If the new CCC has the
cap on R-91, the cap should be
added to the IR interface.
Failure to do so could cause a
problem to develop where there
was not one in the past.