MODIFYING MEDIUM RESOLUTION MONITORS
TO ST AND ARD RESOLUTION
Jc1mes Beck
Grec1ter Southern Dist.
Atlc1ntc1, Georgic1
BonoM
QUESTION
Is it possible to tc1ke c1 medium
resolution monitor 2nd down-
grc1de it to c1 stc1ndc1rd resolu-
tion monitor? The c1pplicc1tion
might be useful for c1 conversion.
Whc1t's the difference?
things" in their gc1mes, c1 higher
resolution thc1n the stc1ndc1rd
wc1s needed. The medium resolu-
tion systems c1re the equivc1-
lent of EGA in the IBM world.
MoDIFYit-G
ANSWER
( es, medium resolution moni-
tors differ from the stc1ndc1rd
resolution monitors used in
video gc1mes in c1 couple c1rec1s.
For one, medium resolution
monitors use c1 different hori-
zontc1I frequency thc1n stc1n-
dc1rd resolution monitors. The
reason? Better resolution (of
course).
Yes, you cc1n ( sort of) convert
those medium resolution moni-
tors
to
"stc1ndc1rd"
frequencies.
The ec1siest
wc1y to do it is
by compc1ring
c1 Wells 4915
(MedRes ver-
sion) sche-
mc1tic to the
4902/03
The "c1lmost" NTSC stc1ndc1rd
resolution systems c1re so-so
c1t best for 19" monitors 2nd
c1bsolutely lousy c1t 25" 2nd
c1bove.
:;1c1me designers who wc1nt to
get c1 decent picture c1t 25" 2nd
to show off 211 the "little
(Stc1ndRes
version)
schemc1tic
2nd doing the
c1ppropric1te
c hc1nges to
the horizontc1I
oscillc1tor cir-
cuit.
LINE
The only snc1g is thc1t the yoke
mc1y need to be chc1nged 2nd the
convergence mc1y not be per-
fect. Although it cc1n be done, I
wouldn't recommend it for gc1me
use c1s the dot pitch will never
be exc1ct. Some c1pplicc1tions,
though, might not be fussy
c1bout the shortcomings: such
c1s c1 test set-up, etc.
FINALLY!
A Guaranteed Solution To ALL Your
RGB Pattern Generation Problems!
Here's the solution you've been looking for! How many times have you
attempted to service color video game monitors without an RGB pattern
generator? Now you can stop spending extra non-profitable time in hap-
hazard service attempts. Your new RGB Pattern Generator will insure good
geometry adjustments, purity and convergence alignments. It's the light
weight, low cost and compact,PRisolution!







New Low-Gray and High-White pattern
for proper color cut-off and gain control
A real-world 6 ft. signal cable
Extra-long 6 ft. A/C cord
Universal MOLEX® signal connectors
Negative composite standard sync.
Multi-pattern generation
One full year parts and labor warranty
Fu/110 day trial. Full refund if not
100% satisfied for any reason!
OnlyS24,g 95
Shipping & Handling Included
(In Continental USA)
~
;;;;;;:flllfi
PRODUCTS RESEARCH INC.
Addison, Illinois 60101
CALL: 1 ·800-525-0093

ST AR*TECH Journal
WILLIAMS SYSTEM
11 COIL
December 1992
PLUNGER PROBLEMS
Kerry Messana
Betson Advance
Syracuse, New Yark
SYMPTOMS
Can't seem to get enough power
out of the upper left ramp
diverter arms on Williams' pin F-
14. (These are similar to the
black plastic diverters used in
High Speed Listed as special
solenoids.) The unloaded/
loaded voltages to these coils
are 33V /24V. They will pull in if
the plunger is held-in partway.
Grounding the collector tabs on
the drivers fires the coils which
are AL-26-1500-02. Every-
thing seems to be reasonable.
SOLUTION
If you hold the plunger in par-
tially and it works properly then
here is the fix: Make the arma-
ture rest further into the coil in
its de-energized state. There is
a way to do this by shimming.
You will also see this problem on
High Speed on its diverter and
on Pinbot on the drop target
reset coil. The bottom line is
that the armature is not far
enough into the coil for the mag-
netism to "grab" it properly.
T RIGGERir-G
As far as special solenoids go
(on System 11that is), they can
be triggered in one of two ways.
One is via a direct switch input,
the other is via CPU control.
Both require the. EN not signal
to be low (flipper relay enabled)
to make them work. They are
usually used on slingshots and
jet bumpers but can be used in
other areas as well. Most early
System 11 games use the di-
rect switch inputs to operate
them, the later ones use
switches located in the switch
matrix to have the CPU read
them and then activate them
through the CPU side. The lat-
ter is the pref erred method
because the CPU can actually
control how many times the coil
is pulsed within a given amount
of time preventing coil and/or
circuitry burnup. On the direct
switch inputs, if you hold the
switch closed it holds the coil
energized which will of course
burn the coil and eventually the
circuitry with it.
All the games use the CPU con-
trolled side during coil self
testing and ball search mode
but the first pinball to use the
CPU side for regular coil activi-
ties was Cyclone. After Cy-
clone some used this method
and others used the traditional
direct switches. Toward the
end of System 11most if not all
used the CPU controlled type.
IDENTlFICA TION
The way to tell which system a
particular pin uses is to look at
J18 on the CPU board. If there is
nothing plugged into it then it
uses CPU controlled speci~
solenoids. If there is a plug - -
then it is switched directly.
The CPU controlled side of the
special solenoids is controlled
by various PIA's (CA2/CB2 set
to be outputs), these signals
are buffered through a 7407
open collector buffer and then
feed the 7402's to turn on the
transistor(s). You can find the
7 407 on sheet 2 of 4 on any
System 11 schematic -it is in
the top/ center of the page. The
outputs of the 7 407 go to the
inputs of the 7402's and are
also connected to the direct
switch inputs ( wire or'ed). You~,
can find this on sheet 1 of 4 in
the top right section. The
7407's outputs are designated
as A through F.