Star Tech Journal

Issue: 1981-May - Vol 3 Issue 3

S*T J
MAY 1981
8
ATARI ''MISSILE COMMAND''
diagnostic tests
INSTRUCTION
1 . Set self-test switch to on
position. Note: entering self-
test will set the HIGH SCORE
TODAY display to 7500.
USE OF TEST
2. Press alpha base fire
button and slam switch simul-
taneously. Release slam
switch first.
A convergence pattern appears on the monitor screen. The background can be
many possible colors. If you are going to converge the monitor, black is the color
you want. To change background color, press either START button. Do not
attempt any convergence adjustments unless you are a qualified color TV
technician!
3. Press omega base fire
button and slam switch simul-
taneously. Release slam
switch first.
Vertical color bars appear on the screen, to permit color hue and brightness
adjustments. Pressing either start button changes the color of the right and left
vertical bars. Do not attempt any color hue or brightness adjustments unless
you are a qualified color TV technician!
4. Press delta base fire
button and slam switch
simultaneously.
White screen appears, and tiny black dots trace all the raster lines from top to
bottom (takes about 4 7 seconds). After this, a blue RAM OK message appears on
the screen, and the+ will reappear. If the message BAD RAM appears and some
or all of the digits 1 thru 8, refer to the following to determine the failing RAM chips.
Test no. 4 display
Bad chip location
BAD RAM 8
P4
BAD RAM 7
N4
BAD RAM 6
M4
BAD RAM 5
L4
BAD RAM 4
K4
BAD RAM 3
J4
BAD RAM 2
H4
BAD RAM 1
F4
Check attract mode display and readjust brightness if necessary.
5. Set self-test switch to
off position.
ROWE BILL CHANGER M o d i f i c a t i o n s
There have been field reports of some BC-20, BC-25, BC-11 and BC-115 Bill Changers spontaneously attempting
to pay out - without input of a bill or coin. This usually results in an immediate shutdown, but in some cases one
change load has been paid out before shutdown.
Upon checking, the Diagnostic Status Code Indicator will display "F", with Fault LED flashing.
The cause of these spontaneous pay-out attempts has been traced to inadvertent "turn-on" of one of the three
bucket solenoid drive transistors - either Q 15, Q 16 or Q 17 - on the Computer Control Center. (This can be a
result of either electrical noise or thermal stress.)
The situation can be corrected in either of two ways:
1.
Replace the defective Computer Control Center with a new or re-worked one from the factory, returning the
defective one for credit. Note: All updated Computer Controls will have a light red dot affixed to the reset
button, and an inspection label dated December 1980 or later.
2.
Re-work the defective Computer Control Center by replacing the three (3) bucket solenoid drive transistors
and the six (6) associated resistors as follows:
Q 15, Q 16 & Q 17 Transistors
REPLACEMENT
Darlington Transistors
Rowe p/n 7-00308-08
(TIP-102 or Tl P-132)
R-54, R-57 & R-58 Resistors
Rowe p/n 7-09901-331
(330 Ohms, 1 /4 W)
R-55, R-56 & R-59 Resistors
Rowe p/n 7-00107-24
(22 Ohms, 1 /2 W)
The replacements mentioned can be ordered from Rowe, Grand Rapids (no charge).
For further Technical information, contact Rowe Field Services at this toll-free number, 800-631-8084.
·s*TJ
GOTTLIEB ~~:-RT
MAY 1981
9
In the past, many operators have commented
that Gottlieb does not provide enough
information on its coils. Hopefully, the following
coil information chart will aid all operators
with quick and proper coil replacement.
SOLENOID COILS
PART
NUMBER
GENERAL
USAGE*
RESISTANCE
(ohms)
NUMBER
WIRE
OF TURNS GAUGE
WRAPPER
COLOR
A-1496
kicking rubbers
pop bumpers
2.95
635
#23
Yellow
A-5194
gong
4.5
780
#24
Blue
A-5195
knocker,
hole kicker
12.3
1305
#26
White
A-16570
hole kicker,
outhole
15.5
1450
#27
Green
A-17875
flippers
2.8/40.0
560/1100
#24/31
Yellow
A-17891
5 bank reset
3.35
850
#22
White
A-18102
3 bank reset, 7 bank
reset uses 2
9.0
1430
#24
Red
A-18318
4 bank reset
6.7
1130
#24
Orange
A-19300
ball kicker
7.8
1075
#25
Orange
A-20095
super flipper
1.55/35.5
450/900
#22/31
Red
RELAY COILS
A-16890
Q, T, and coin
lockout relays
231.0
4000
#35
Orange
A-17564
gate relay
156.0
3400
#34
White
A-18642
memory/
drop targets
58'.0
1590
#33
White
*Coils may vary from game to game. Check game manual for exact coil usage.
Normally, all coils are powered by +24 VDC.